MTMS / MTMD Series Multi-péngkolan Electric Actuator
Ciri
Modél | Tipe Dasar | Tipe Intelligent (LCD) | Tipe SuperIntelligent (SLCD) | ||||
Rentang torsi | 35-3000N.m | ||||||
Laju | 50Hz | 18, 24, 36, 48, 72 rpm | 18, 24, 36, 48, 72, 96, 144, 192 rpm | ||||
| 60Hz | 21, 29, 43, 57, 86 rpm | 21, 29, 43, 57, 86, 115, 173, 230 rpm | ||||
Suhu Ambient | ▪-30℃~70℃(-22OF~158OF)Pilihan:-40℃~60℃(-40OF~140OF)JB/T8219 | ||||||
Tingkat Noise | ▪Kirang ti 75dB dina 1m | ||||||
Panganteur listrik | ▪TwoNPT3/4,OneNPT11/2 | ||||||
Perlindungan Ingress | ▪IP67,Pilihan: IP68 | ||||||
Ukuran sambungan | ▪ISO5210(Thrusttype\torquetype)jeungJB2920(Threeclawtype)▪N/A | ||||||
Spésifikasi Motor | ▪KelasF, kalayan palindung termal nepi ka+135 | ||||||
Sistem Gawé | Hurung-Pareum | ▪Tipe On-off: S2~15 mnt, leuwih ti 600 kali sajam mimiti | |||||
| Modulasi | S4 ~ 25%, nepi ka 600 triggersperhour | |||||
Tegangan lumaku | ▪3fase:AC380V(±10%)/50/60Hz(±5%) | ||||||
| 3 fase 3 kawat | ||||||
| ▪Pilihan: 1faseAC220V(1...3seri | ||||||
Input | Hurung-Pareum | ▪Diwangun-incontactsfor5Aat250VAC | ▪Asupkeun AC/DC24, | ▪20-60VAC/DCor60-120VAC | |||
|
| (gumantung kana kotak kontrol) | AC110/220Vinput (opsional) | ▪Optoeléktronikisolasi | |||
|
| ▪Optoeléktronikisolasi | |||||
| Modulasi | ▪Sinyal Input: 4~20mA; | |||||
|
| 0 ~ 10V; 2 ~ 10V | |||||
|
| ▪Impedansi kaluaran:≤750Ω | |||||
|
| (4~20mA) | |||||
Eupan Balik Sinyal | Hurung-Pareum | ▪Tutup kontak klep | ▪Lokal/kontak jarak jauh | ▪RelayX5(4bisa disetel ka "alami | |||
|
| ▪Openthevalvecontact | ▪Integrated faultcontact | buka"atawa"naturalclosed"kontak. | |||
|
| ▪Kontak sinyal torsi bubuka | (Kapasitas kontak: 5Aat250VAC) | 1integratedfaultcontact) | |||
|
| Panutup kontak sinyal torsi | ▪Kontak sinyal torsi bubuka | A.Singleormulti-phasepowerdown | |||
|
| ▪Kontak sinyal torsi nutup | B.Controlcircuitpowerfailure | ||||
|
| C.Selectionswitchiplaceorthe | |||||
|
| stopposition | |||||
|
| D.Motortemperatureprotectorjumps | |||||
|
| peureum | |||||
Rusak | Hurung-Pareum | ▪Motoroverheating, | ▪Faultalarm terpadu: | ▪Jammedvalveprotection | |||
Eupan balik |
| overtorquecontacts | Poweroff, motor overheating, | ▪Losesignalprotection | |||
|
| Fase leungitna, overtorque, | ▪Koréksi fase | ||||
|
| losesignal, ESD, kaluaran terminal | ▪Saklar torsi | ||||
|
| ▪Panyalindungan termal | |||||
|
| ▪Panyalindungan balik instan | |||||
|
| ▪Alarm séjén | |||||
| Modulasi | ▪SupportSignalReverseandLoss | |||||
|
| Signa | |||||
|
| ▪DeadZone: 0 ~ 25,5% adjustablerate | |||||
|
| jero pinuh stroke. | |||||
|
| ▪Selang waktu:0~25.5s(bisa diatur) | |||||
Indikasi | ▪Pointertypeopenindicator | ▪layar LCD | ▪4-levelgrayscaleLCDscreen | ||||
| piring | Buka pinuh / Tutup pinuh / jauh / | indikator bubuka,Buka pinuh/pinuh | ||||
| faultindicator (tampilan digital tina | nutup / jauh / faultindicator | |||||
| persentase bubuka) |
Tulis pesen anjeun di dieu sareng kirimkeun ka kami